Advance acoustic Terra 128B Specifications

Browse online or download Specifications for Floor Machine Advance acoustic Terra 128B. Advance acoustic Terra 128B Specifications [de] [es] [fr] [it] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
© Semiconductor Components Industries, LLC, 2014
April, 2013 − Rev. 4
1 Publication Order Number:
R3710/D
RHYTHM R3710
Preconfigured DSP System
Description
RHYTHMt R3710 is a preconfigured DSP system designed
specifically for Invisible−In−Canal (IIC) hearing aid devices.
Available in the industry’s smallest hybrid form−factors, it is well
suited for hearing aid designs that are placed deep in the ear canal.
Using miniaturized advanced packaging techniques,
ON Semiconductor enables hearing aid manufacturers to take
advantage of the highly compact size to produce IIC hearing aids that
fit a greater portion of the market. Featuring iSceneDetectt
environmental classification, adaptive noise reduction, feedback
cancellation, and up to 8−channel WDRC, R3710 provides the
advanced features and performance level typically found in high−end
products.
Acoustic Environment Classification − The iSceneDetect
environmental classification algorithm is capable of analyzing the
hearing aid users acoustic environment and automatically optimizes
the hearing aid to maximize comfort and audibility.
iLogt 6.0 Datalogging − Enables the recording of various hearing
aid parameters such as program selection, volume setting and ambient
sound levels. The sampling interval can be configured to record from
every 4 seconds up to once every 60 minutes. The fitting system can
present the data to help the fitting specialist fine tune the hearing aid
and counsel the wearer during follow up visits.
Evoket Advanced Acoustic Indicators − Allows manufacturers
to provide more pleasing, multi−frequency tones simulating musical
notes or chords to indicate events such as program or volume changes.
Adaptive Feedback Canceller − Automatically reduces acoustic
feedback and allows for an increase in the stable gain while
minimizing artifacts for music and tonal input signals.
Adaptive Noise Reduction − The adaptive noise reduction
algorithm on R3710 monitors noise levels independently in 128
individual bands and employs advanced psychoacoustic models to
provide user comfort.
Tinnitus Masking − R3710 is equipped with a noise source that can
be used to mask tinnitus. The noise can be shaped, attenuated, and duty
cycled then summed into the audio path either before or after the
volume control.
In−situ Tone and Noise Generator − The narrowband noise and
tone stimulus feature can be used for in−situ validation of the hearing
aid fitting. The frequency, level and duration of the stimuli are
individually adjustable.
http://onsemi.com
PAD CONNECTION
MARKING DIAGRAM
R3710
XXXXXX
R3710 = Specific Device Code
XXXXXX = Work Order Number
VIN2
VIN1
MS2
DVC
OUT+
OUT−
NC
VC
MS1
SDA
CLK
VB
MGND VREG
GND2 GND1
1
(Bottom View)
2
161514
13
12
11
10
9
3
4
5
678
See detailed ordering and shipping information on page 15 o
f
this data sheet.
ORDERING INFORMATION
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - Preconfigured DSP System

© Semiconductor Components Industries, LLC, 2014April, 2013 − Rev. 41 Publication Order Number:R3710/DRHYTHM R3710Preconfigured DSP SystemDescription

Page 2 - BLOCK DIAGRAM

RHYTHM R3710http://onsemi.com10with the rest of the audio through the device when the VC isadjusted. If the noise is injected after the VC then it is

Page 3

RHYTHM R3710http://onsemi.com11enabled it is highly recommended that the Squelch be turnedon in all channels and that the Squelch thresholds be setabo

Page 4

RHYTHM R3710http://onsemi.com12The behavior of the MS switches is controlled by two mainparameters in IDS.• MSSmode: this mode determines whether a co

Page 5

RHYTHM R3710http://onsemi.com13Mode 3: Static Switch on MS1 and MS2This mode uses two static switches to change memories.Table 8 describes which memor

Page 6

RHYTHM R3710http://onsemi.com14audio output being enabled. This gives the user time toproperly insert the hearing aid before the audio starts,avoiding

Page 7

RHYTHM R3710http://onsemi.com15from cloning a device’s EEPROM because thefingerprint cannot be overwritten. Special functions canbe used in fitting so

Page 8 - Adaptive Feedback Canceller

RHYTHM R3710http://onsemi.com16Table 10. PAD POSITION AND DIMENSIONS (mil)Pad No. Pad NamePad Position Pad DimensionsX Y Xdim Ydim1 VIN2 −71 44 23 232

Page 9

RHYTHM R3710http://onsemi.com17Table 11. PAD POSITION AND DIMENSIONS (mm)Pad No. Pad NamePad Position Pad DimensionsX Y Xdim Ydim1 VIN2 −1.8034 1.1176

Page 10

RHYTHM R3710http://onsemi.com18PACKAGE DIMENSIONSDimension units are in inches.Dimensions in parentheses are in millimeters, converted from inches and

Page 11

RHYTHM R3710http://onsemi.com2Other Key Features − R3710 also supports the followingfeatures: built−in feedback path measurement, cross fadingbetween

Page 12

RHYTHM R3710http://onsemi.com3SPECIFICATIONSTable 1. ABSOLUTE MAXIMUM RATINGSParameter Value UnitsOperating Temperature Range 0 to +40 °CStorage Tempe

Page 13

RHYTHM R3710http://onsemi.com4Table 2. ELECTRICAL CHARACTERISTICS (Supply Voltage VB = 1.25 V; Temperature = 25°C) (continued)Parameter UnitsMaxTypMin

Page 14

RHYTHM R3710http://onsemi.com5Table 3. I2C TIMINGParameter SymbolStandard Mode Fast ModeUnitsMin Max Min MaxClock Frequency fPC_CLK0 100 0 400 kHzHold

Page 15

RHYTHM R3710http://onsemi.com6Figure 2. I2C Mode Timing

Page 16

RHYTHM R3710http://onsemi.com7TYPICAL APPLICATIONS3k753k75LP FILTEROUTFigure 3. Test CircuitNoise Reduction (128 bands)Graphic EQ (16 bands)128 bandsW

Page 17

RHYTHM R3710http://onsemi.com8SIGNAL PATHThere are two inputs into the audio signal path. The firstinput is the front microphone and the second input

Page 18 - R3710−CEAA

RHYTHM R3710http://onsemi.com9Figure 5. Adaptive Feedback Canceller (AFC)Block DiagramGΣH’H+−Feedback pathEstimated feedbackFeedback Path Measurement

Comments to this Manuals

No comments